BC-7600 Series Auto Hematology Analyzers
Auto Hematology Analyzers

BC-7600 Series

One Tube, One Process with Maximum Efficiency

One Tube, One Process with Maximum Efficiency

BC-7600 Series Auto Hematology Analyzers provide comprehensive solutions for complete blood count (CBC), differential white blood cell count (DIFF), hematological malignant cells, low-value WBC/PLT, PLT clumps, etc. They also support the analysis of body fluids.

BC-7600 Series adopts SF-Cube principal, which has a good correlation with other Series for cross-checking of patient results.

Comprehensive Solution for Accurate PLT Results

High Sensitivity and Specificity of Blast Flagging Capability for Preliminary Screening

The coordinated analysis technology of WNB and DIFF scattergarms give sensitive alerts for “Blasts" with high specificity to reduce unnecessary labor-intensive manual microscopy.

DIFF 3D scattergram

Coordinated analysis

WNB 3D scattergram

Blasts
Abn. Lymph/blast?
Abn. Promyelocyte/blast?

The detection concentration is as low as 0.03×10?/L

Flag Towards Precise Screening of Infectious Mononucleosis (IM)

DIFF 3D scattergram

3D Scattergram of typical infectious mononucleosis

Alert precisely for reactive lymphocytosis caused by infectious mononucleosis

through the distribution characteristics of scatter plots

Reactive Lymph-IM?
Higher Specificity for Hematological Malignant Cells

By using the HMC scattergram and combining information from the DIFF and WNB scattergrams, precise alarms for blast cells, abnormal lymphocytes, and abnormal promyelocytes are achieved, effectively aiding clinical diagnosis.

The specificity has been improved by approximately 40% compared to CD mode.

Abnormal promyelocyte

Blast

Abnormal lymphocyte

Others

Typical samples of
acute promyelocytic leukemia (APL)

Blasts

Abn. promyelocyte?

Typical samples of
acute monocytic leukemia (M5)

Blasts

Typical samples of
hairy cell leukemia

Abn. Lymph?

Blasts

HMC 3D scattergram

Comprehensive Solution for Accurate PLT Results

Brand new PLT-H in every CD test
PLT-O with Multiple Counting for Low-count Platelet

There is no need to re-aspirate samples. The instrument will automatically conduct 8 times statistical analysis on low PLT count samples to improve the detection accuracy.

Scattergram before and after Auto 8x PLT-O counting

PLT-O with automated PLT-clumps de-aggreation technology

It solves the problem of falsely low PLT count samples caused by EDTA induced pseudo-thrombocytopenia.

Automatic retraction and re-testing with PLT-O

CBC + DIFF + ESR in one test provide reliable ESR results with greater ease
The BC-7600 series integrates an automatic ESR module in a hematology analyzer. It can also generate both CBC & ESR results in one test within 40 seconds. In addition, it saves the costs that would otherwise be incurred for the purchase, maintenance, consumables, and storage space of a separate ESR analyzer. Compared with the traditional Westergren method, this method performs better in quality traceability, repeatability, speed, safety, and level of automation.
Accurate
Cost-effective
Automatic
Great correlation with the Westergren method
Same QC and calibrator as in the BC-6800Plus Series
Combined examination helps to avoid the interferences of dehydration, polycythemia vera and anemia on ESR results
BC-7600 Series Auto Hematology Analyzers - High correlation coefficient between Easy-W ESR and Westergren method
The integrated instrument is capable of both CBC and ESR detection
Takes up the space of only one analyzer
BC-7600 Series Auto Hematology Analyzers
Report CBC + ESR results together in 40 seconds
Standardize the testing process and reduce the instability of testing
Automation can reduce the biosafety hazards that may otherwise be introduced by a manual method
BC-7600 Series Auto Hematology Analyzers - automation ESR test results